Mounting, Mounting procedure on a 1-inch ips vertical pipe, Inverted mounting – Vaisala WS425 User Manual

Page 26

Advertising
background image

USER'S GUIDE____________________________________________________________________

26 __________________________________________________________________ M210361EN-E

Mounting

Mounting Procedure on a 1-inch IPS Vertical Pipe

Use the following procedure to mount the sensor normally to a vertical 1-
inch International Pipe Standards (IPS) pipe. WS425FIX30 is suitable for
the 1-inch IPS vertical pipe and WS425FIX60 is suitable for a 60-mm
vertical pipe (Europe). See Figure 2 on page 24 for details.

To mount the sensor, do the following:

1.

Remove the hex-socket bolt or standard screw shown in Figure 2
on page 24 (use 3/16-inch Allen ke
y or a crosshead screwdriver).

2.

Connect the cable to the sensor, routing it through the adapter.

3.

Attach the adapter to the sensor body and tighten the bolt.

4.

Run the cable out of the adapter slot between the sensor and the
clamp. Optionally, you can run the cable inside the vertical pipe.

5.

Place the sensor on the pipe and slightly tighten the clamp’s bolt.

6.

Align wind direction as explained in section Alignment on page 27.

Inverted Mounting

To provide additional protection agains the accumulation of snow and
interference from birds, the WS425 can be installed so that the transducer
arms face down. Note the following:

- The WS425 must be in the serial operation mode. See section Serial

Mode on page 38.

- Configure the Head Orientation parameter accordingly. See section

Head Orientation on page 49.

- Protect the connector from rain and snow.

WARNING

Do not install the WS425 upside down in an airport application.