USER'S GUIDE____________________________________________________________________

60 __________________________________________________________________ M210361EN-E

When the previous command WS aV! is given, the response is the
following:

a<watchdog><WS_unit><SDI-mode><spare><CR><LF>

where

a

=

The sensor address.

<watchdog>

=

The number of times the watchdog has
triggered. Ideally should be zero. Format: +(c)c

<WS_unit>

= Wind speed unit. The options are:

+0 = mph

+1 = kt

+2 = km/h

+3 = m/s

<SDI-mode>

= Current submode setting. The options are:

+0 = SDI-12 submode A

+1 = SDI-12 submode B

<spare>

=

1 digit for factory use, format: +c

<CR><LF>

=

Terminates the response.

The above are verification data fields.

Continuous Measurements (aR0!)

A sensor that is able to continuously monitor the phenomena to be
measured, does not require a start measurement command (M!). The data
can be read directly with the R0! command.

WS425 uses this command when the sensor is set to work in SDI-12
submode B. The command retrieves averaged wind data and gust wind
data. The averaging time window is selectable between 3 and 3600
seconds.

The command is the following:

aR0!

where

a

=

The sensor address.

R0

=

The send continuous measurements command.

!

=

Terminates the command.