Place sensor in submode b (axqx;c.c;n;yyyy!) – Vaisala WS425 User Manual

Page 64

Advertising
background image

USER'S GUIDE____________________________________________________________________

64 __________________________________________________________________ M210361EN-E

The response is the following:

a+x<CR><LF>

where

a

=

The sensor address.

x

=

The currently active submode. The options
are:

0 = submode A

1 = submode B

<CR><LF>

=

Terminates the response.

Place Sensor in Submode B (aXQx;c.c;n;yyyy!)

This command sets the sensor into submode B which enables calculation
of averaged wind data and gust wind speed and direction.

The command is the following:

aXQx;c.c;n;yyyy!

where

a

=

The sensor address.

XQ

=

The place sensor in submode B command.

x

= The desired wind averaging method. The

options are:

0 = use scalar averaging

1 = use vector averaging

c.c

= The wind direction coasting threshold in

the current wind speed units. The coasting
can only be used with scalar averaging.

n

= The number of samples that form the gust

wind speed and direction value (1 Hz
sampling). The valid range is 1 to 9.

yyyy

= The length of averaging window [s]

!

=

Terminates the command.

The response is the following:

a<CR><LF>

where

a

=

The sensor address.

<CR><LF>

=

Terminates the response.