Serial mode default settings for europe, Configuration menu – Vaisala WS425 User Manual
Page 39
Chapter 4 ________________________________________________________________ Operation
VAISALA _______________________________________________________________________ 39
Serial Mode Default Settings for Europe
Operation Mode:
NMEA Extended
Wind Speed Units:
Meters/Second
Average Interval (seconds):
3
Averaging Method:
Scalar
Output Interval (seconds, 0 for polled):
1
Sensor ID Character:
A
Wind Direction Coast Threshold (speed units): 0.0
Head Orientation:
Up
Baud Rate:
9600b
Parity: None
Data Bits:
8
NOTE
These default settings for Europe are used for product ordering options
x2xxx (for example, WS425 A2A1A, where the number 2 refers to the
default settings).
Configuration Menu
The configuration menu can be opened by typing
Open
or
Open <id>
where
<id>
is the identification character of the sensor.
If the sensor has been running for more than five seconds, use the
currently active baud rate and other communication settings. There is a
short timeout in typing in the characters. Therefore, type the OPEN
command followed by ENTER relatively fast.
The OPEN command displays the following menu (on the next page):