Serial mode default settings for europe, Configuration menu – Vaisala WS425 User Manual

Page 39

Advertising
background image

Chapter 4 ________________________________________________________________ Operation

VAISALA _______________________________________________________________________ 39

Serial Mode Default Settings for Europe

Operation Mode:

NMEA Extended

Wind Speed Units:

Meters/Second

Average Interval (seconds):

3

Averaging Method:

Scalar

Output Interval (seconds, 0 for polled):

1

Sensor ID Character:

A

Wind Direction Coast Threshold (speed units): 0.0
Head Orientation:

Up

Baud Rate:

9600b

Parity: None
Data Bits:

8

NOTE

These default settings for Europe are used for product ordering options
x2xxx (for example, WS425 A2A1A, where the number 2 refers to the
default settings).

Configuration Menu

The configuration menu can be opened by typing

Open

or

Open <id>

where

<id>

is the identification character of the sensor.

If the sensor has been running for more than five seconds, use the
currently active baud rate and other communication settings. There is a
short timeout in typing in the characters. Therefore, type the OPEN
command followed by ENTER relatively fast.

The OPEN command displays the following menu (on the next page):