Chapter 4 ________________________________________________________________ Operation

VAISALA _______________________________________________________________________ 65

Reset the Sensor to Submode A Command (aXS!)

When the sensor is set to submode B in order to compute averaged wind
data, the sensor will stay in mode B until a
2-hour time period has elapsed. This computation period can be aborted
earlier by issuing the command (XS!).

The command is the following:

aXS!

where

a

=

The sensor address.

XS

=

The reset sensor to submode A command.

!

=

Terminates the command.

The response is the following:

a<CR><LF>

where

a

=

The sensor address.

<CR><LF>

=

Terminates the response.

Check Current Measurement Unit (aX*!)

The command is the following:

aX*!

where

a

=

The sensor address.

X*

=

The check current measurement unit command.

!

=

Terminates the command.