0040501000 4511

Operating and installation instructions

Thrust actuator ARI-PREMIO

Fig. F:

- Screw the coupling (pos. 50.27) firmly into the torsion safety feature

(pos. 50.32) and secure in place using grub screw M6 (pos. 50.35).

- Run valve to lowest position.
- Clip lift dial (pos. 50.23) onto yoke in such a way that top edge of torsion safety

feature is in alignment with tip of arrow mark on lift dial.

- Run valve to both final positions and check to ensure that these are safely

reached

- Carry out electrical connection (see point 5.4).
- Set travel switch S3 (see point 5.5.3.2).