ARI Armaturen ARI-PREMIO User Manual
Page 38
Page 38
0040501000 4511
Operating and installation instructions
Thrust actuator ARI-PREMIO
5.5.9 Electronic position indicator (RI21) and position controller (ES11) together in
the actuator
The electronic position indicator RI21 and the electronic position controller ES11 can be
build-in together in the ARI-PREMIO (Except: 5 kN 24V 1,0/1,2 mm/s; 12 kN 24V;
15 kN 24V).
It must be used a double potentiometer with 1000/1000 Ohm.
To install the RI21 and ES11 proceed as follows:
- Switch-off mains voltage and safeguard to prevent it from being switched back on again
accidentally.
- Loosen collar nut / countersunk screw on hood, carefully remove hood.
- Mount RI21 and ES11 with mounting kit according to Fig. 18.
Fig. 18: Installing RI21 / ES11 at the same time as ARI-PREMIO 2.2 – 5 kN
Pos.
Designation
Pos.
Designation
50.67
Potentiometer
50.82
Head cap screw
DIN EN ISO 4762 - M4x12
50.78/79 Option ES11 or RI21
50.106
Metal sheet ES11 and RI21
50.81
Head cap screw
DIN EN ISO 4762 - M4x8
50.108
Distance bold