3 technical data – dc module – ARI Armaturen ARI-PREMIO User Manual

Page 44

Advertising
background image

Page 44

0040501000 4511

Operating and installation instructions

Thrust actuator ARI-PREMIO

5.5.13.3 Technical data – DC module

Type

PREMIO-24V DC

Thrust force

kN

2.2

5

12

15

Travel distance

mm

50

80

Duty classification in accordance with
EN 60034

S3 80% DC 1200 c/h

Control speed

mm/s

0.38

1.00

0.38

0.79

0.38

Supply voltage

24V DC ± 10% BLDC motor

Power consumption

VA

7

14

30

Max. 72

Protection to DIN 60529

IP65

Storage temperature

°C

-40°C ... +85°C

Max. permissible ambient
temperature

°C

-20°C ... +70°C

Handwheel

Yes (rotating during operation)

Yes (engageable)

Operation:

3-step: 24V DC/AC or 90 to 253V AC

Pole changing for 24V DC (with optional board support)

Max. conductor cross-sections

Supply voltage: 2.5mm²

3-step input: 2.5mm²

Control signals: 2.5mm²

Mounting position

Any, exception: the motor must not be suspended downwards

Gear lubricant

Klüber Isoflex Tobas NB152

Molyduval Valenzia H2

Weight

kg

5.4

6

10.5

Accessories
Electronic position controller

Type ES11

- For control with 0(2)...10V or 0(4)...20mA;

electrical isolation between mains voltage and control signal

- Incl. potentiometer

Electronic position indicator

Type RI22

- Analogue output for position feedback 0(4)...20mA, optional

switching to 0(2)-10V, output can be inverted; electrical isolation
between mains voltage and position feedback signal

- Optional display (for indicating position feedback signal in mA or V)
- Incl. potentiometer

Potentiometer

Conductive plastic
max. 2 pcs.

500, 1000, 2000, 5000 ohm; 1 W

Wire‚ Äö
max. 2 pcs.

100, 200 ohm; 1 W

Contactless
max. 1 pc.

Only in conjunction with RI22
Feedback signal corresponds to RI22

Board support for pole changing at
24V DC

For 3-step control with pole changing (two-wire circuit). The direction of motor rotation is
changed by reversing the supply voltage

2 additional intermediate position
switches S4, S5
Information:

Gold contacts should be used for low
switching capacities and aggressive
atmosphere.

Standard

Zero potential, switching capacity 10A, 250V~

Low-voltage

Zero potential, with gold contacts, max. switching capacity 0.1A,
4-30V

Battery-operated emergency reset
(available from 2012 approx.)

- Mounted to the outside of the actuator
- In the event of a power failure, the actuator is moved into a defined end position (extending

or retracting) by battery power

- Battery capacity after one year without recharging: > 85%
- Sufficient battery capacity for at least 5 runs

Advertising