The S column reveals the stage of the test at the time the table was created — D = data transfer, S =
synchronization.

The next 4 columns indicate bytes and packets sent and received.

The last three columns indicate the port with which the interface is communicating.

The test should be run until at least one test loop (LP = 1) has completed. More loops can be run if
errors appear, to determine if the errors repeat or are just an artifact of the test procedure. If there
is a hardware defect, the value in the E%% column will be large.

Below the General Statistics Table, the time in test and total errors are indicated. If an error occurs, typing “E”
will show an Error Table with information about the error. Typing “S” will show a Status Table, indicating the
profile being tested at the time “S” was pressed. This does not supply information that can be interpreted by a
user.