Cyclades-PR2000

37

Chapter 4 - Step-by-Step Instructions

Menu CONFIG=>MULTILINK=>MULTILINK CIRCUIT NUMBER=>ADD/MODIFY INTERFACE
Parameter

Example

Your Application

Slot N

SWAN 1

Type of Interface

Main

Time to Activate
Backup After This
Link Goes Down

5

Time to Deactivate
Backup After This
Link Returns

20

FIGURE 4.18 ADDITION OF THE PRIMARY (MAIN) LINK

Menu CONFIG=>MULTILINK=>MULTILINK CIRCUIT NUMBER=>ADD/MODIFY INTERFACE
Parameter

Example

Your Application

Slot N

SWAN 2

Type of Interface

Backup

Time to Activate
Backup After This
Link Goes Down

Zero, since this link IS the backup. (A
backup can itself have a backup, but
this is not done in this example.)

Time to Deactivate
Backup After This
Link Goes Up

Zero, since this link IS the backup.

Cost

One. Indicates the relative priority of
this backup link, which is unnecessary
since this example has only one.

FIGURE 4.19 ADDITION OF THE SECONDARY (BACKUP) LINK