17

status LED’s will turn “Green”, The LCD Display will display “Vi, Vo, FQ, Io“.

THE, inverter will start operating normally.

Set the power switch to the “OFF” position. THE, inverter stops and all

the lights that are on will, go off.

4-4. Protections Features

Model

DC Input (VDC)

Over Temperature Protection

Over Voltage

Under

Voltage

Alarm

Under Voltage

INTERIOR

HEAT SINK

Shut-down Restart

Shut-down Restart Shut-

down Restart

Shut-

down Restart

24 V 30.1~34.1 28~32 19~23 18.1~22.1 23~27 65℃ 45℃ 105℃ 75℃

48 V

60.1

56~60 38~46 36.1~44.1 46~54

5. Front LCD Panel – Display & Setup

5-1. LCD Panel Indications

5-1-1. Set the Power Switch to the “ON” position. THE, inverter starts working

normally. The inverter will be operating in normal condition when either

of the following messages are displayed on the LCD screen:

FQ=60.0 Io =8.5

Vi =24.0 Vo=115

LED's

INDICATORS

LCD

DISPLAY

LCD DISPLAY

SELECTION BUTTONS

5-1-2. LED Indications:

AC GRID: Displays AC input status.

AC Input

LED Status

AC input and DC-AC Inverter

Output are Synchronous

Green

AC input ON

Orange

AC input OFF

Off

Note. Synchronous means that the: grid AC input frequency and DC-AC

inverter output frequency or phase are the same (See details in