Signal description, Rs-232 communication and operation, Sr series inverter – Samlex America SR1000-148 User Manual

Page 26: Computer power inverter

Advertising
background image

SR Series Inverter

25

15). Overload Alarm: Sets the overload alarm. When the output power is

higher than the set value, the unit will sound “beep”

to remind that the unit is going to shutdown. At the

same time, the internal Dry Contact Relay will

open/close (See details in Section 3-1-6).

Default= 100%

Setting range= 50%~110%

6. RS-232 Communication and Operation

6-1. Operation of RS-232 Serial Port:

6-1-1. This unit uses a standard 9-Pole D connector and three of the RS232 signal

lines:

1

2

3

4

5

6

7

8

9

Signal description

PIN

N.C

1

RXD

2

TXD

3

DTR

4

GND

5

DSR

6

RTS

7

CTS

8

N.C

9

6-1-2. The connection between this unit and the computer is as follows:

Computer

Power Inverter

RXD

GND

D

X

T

D

X

T

GND

RXD

DSR

RTS

DTR

CTS