7. Information

7-1. Troubleshooting

Problems and Symptoms

Possible Cause

Solutions

No AC Power “Output”
a. LCD Panel Display

“OLP Shutdown”

Short circuit , wiring

error. over loading.

Check AC wiring for

short circuit .

Reduce load.

b. LCD Panel Display

“OVP Shutdown”

Over input voltage

(OVP)

Check input voltage

Reduce input voltage

c. LCD Panel Display

“UVP Shutdown”

Low input voltage.

(UVP)

Recharge battery.

Check connections

and cables.

d. LCD Panel Display

“OTP shutdown”

Thermal shutdown.

(OTP)

Improve ventilation.

Make sure ventilation,

grilles / slots of the

inverter are not

obstructed. Lower

ambient temperature.

7-2. Warranty

We guarantee this product against defects in materials and workmanship for

a period of 36 months from the date of purchase and will repair or replace

any defective power inverters if you directly returned them to us with

postage paid.

Please note that Cotek is only responsible for ensuring our products are

operational before delivering. This warranty will be considered void if the

unit has been misused, altered, or accidentally damaged. Cotek is not liable

for anything that occurs as a result of the user’s fault.

8. Appendices

WARNING:

Do not open or disassemble the SR series Inverter.

Attempting to service the unit may cause risk of

electrical shock or fire.