Not used, Setting menu, Rs-232 – Samlex America SR1000-148 User Manual

Page 29: Baud rate, Sr series inverter

Advertising
background image

SR Series Inverter

28

<Function Code> Setting Menu <Function Code> Setting Menus

0

LCD Contrast

9

UVP Recovery

1

LCD Auto-off

10

UV Alarm

2

RS232 Baud-rate

11

O/P Voltage

3

Buzzer Setting

12

O/P Frequency

4

Alert Setting

13

Sync Frequency

5

NOT USED

14

Bypass Relay

6

OVP Setting

15

Overload Alarm

7

OVP Recovery

16

NOT USED

8

UVP Setting

17

NOT USED

2). Command to query the Functions No:

Format: FUNC?

After “Enter”, the unit’s “Function Code” appears on the PC screen.

3). Command to query the set value of the Function:

Format: SETT?

After “Enter”, the existing set value of the function appears on the

PC screen.

4). Command to set or adjust the value of the Function:

Format: SETT <value>

After “Enter”, the new value of the Function is set Choose the

<value> of the function as follows:

FUNC 0: LCD Contrast

Setting Menu

SETT <value>

LCD Contrast

0~100

FUNC 1: LCD Auto-off

Setting Menu

SETT <value>

LCD Auto-off

Disable~250

FUNC 2: RS232 Baud rate

Setting Menu SETT <value>

Baud rate

RS-232

Baud rate

0

1200

1

2400

2

4800

3

9600

Advertising