SR Series Inverter

27

6-3-2. Command format:

This unit supports the following command format.

There should always be a CR (0DH) and a LF (0AH) appended to the

command while sending the command to this unit.

1). Command to switch the Power ON/OFF:

Format: Power <value>
Example: A space (ASCII code 20H) is needed between Power and

<value>.

<value> can be one of the following.
“0”: Power off
“1”: Power on

2). Command to query the Output Frequency:

Format: FRQ?
After “Enter”, the unit’s “Output Frequency” appears on the PC screen.

3). Command to query the Output Voltage:

Format: VOL?
After “Enter”, the unit’s “Output Voltage” appears on the PC screen.

4). Command to query the Output Current:

Format: AMP?
After “Enter”, the unit’s “Output Current” appears on the PC screen.

5). Command to query the Input Battery Voltage:

Format: BAT?
After “Enter”, the unit’s “Input Voltage” appears on the PC screen.

6-3-3. Command for accessing Setup Menus and adjusting values:

1). Select the Setup Menus with the help of Function Codes:

Format: FUNC <Function Code>
After “Enter”, the Setup Menu for the Function Code will be called.

The <Function Code>= 0~17, as follows: