Axis Communications 2460 User Manual

Page 26

Advertising
background image

Setting up Events and Alarms

AXIS 2460 User’s Manual

26

These three options can be selected in any combination, e.g.

• Alarm 1 - Active
• Alarm 2 - Inactive
• Alarm 3 - -----
• Alarm 4 - Active

If the alarm input is shown as Disabled, click the Alarm Settings button to the right, to go

to the alarm configuration page.

Recording Buffer Settings

Pre-Buffer -

Specify the length of the period to record immediately preceding the event.

Configurable in seconds, minutes or hours. Useful for e.g. seeing what happened

immediately before a fire alarm. This setting is optional.

Recording Duration -

Specify the length of time to record. Used to specify an exact duration,

this setting can be used to e.g. take snapshots of predictable conditions of a constant

length and which do not vary. Configurable in seconds, minutes or hours. This setting is

optional.

Pan/Tilt/Zoom Control

If a camera uses a Pan/Tilt/Zoom (PTZ) device, it is possible to define which preset position

the device will move to when the event is triggered.

If several events are recording at the same time, the PTZ device will move to the preset

position for the event that has the highest priority. When this event stops recording, the
PTZ device will then assume the preset position for the next active event that has the

highest priority.

Preset positions for each camera are defined under Camera Options.

Output Relay

To display the checkbox for the Output relay in the event settings, it must first be enabled

on the Alarm Settings page. This will enable the checkbox for all events. Once the
checkbox is visible, the output relay can then be enabled or disabled independently for

each event. Once the output relay has been activated by the event, it will remain active as

long as the event is recording.

If the heading for the Output relay is marked as

Disabled

, click the Alarm Settings button

to go to the alarms page.

Advertising