Controlling and monitoring, Relay output, Digital inputs – Axis Communications 2460 User Manual

Page 66

Advertising
background image

Unit Connectors

AXIS 2460 User’s Manual

66

Controlling and Monitoring

By entering http requests in your browser’s URL field, you can:

• drive the relay output high or low
• monitor the status of the 4 digital inputs
This requires you to have root access to the AXIS 2460 and consequently, to supply a user
name and password. Login as root and supply the root password (default = pass).
Tip!

Relay Output

You can use the supported relay output to directly drive a maximum load of 24V AC/DC at

100mA. By connecting additional relay circuitry, it can also drive heavier loads.

The output relay is controlled using http requests, as defined in the following examples:

Example 1: -

Set output 1 ON.

Example 2: -

Set two 300ms pulses with 500ms delay between the pulses on output 1.

Example 3: -

Wait 1 second before setting output 1 ON.

Digital Inputs

Four digital inputs allow the AXIS 2460 to be configured for time and alarm based image

recording. For example, by connecting a motion detector to a digital input, it is a relatively

simple procedure to send a single image (or video stream) to a remote imaging library each
time the detector is activated. These inputs can be driven by voltages of 5-24V.

Querying the Status of Digital Inputs

The status of the four supported digital inputs can be queried in exactly the same way as

the relay output. Simply enter the following URL to query the status of the digital inputs:

Example: -

Monitor data on input ports 1, 2, 3, and 4.

Developers wishing to create applications incorporating sophisticated alarm conditioning using the
relay output and digital inputs are encouraged to read the Camera API, HTTP-Interface Specification,
available from the Axis Web at www.axis.com

http://myserver/axis-cgi/io/output.cgi?action=1:/

http://myserver/axis-cgi/io/output.cgi?action=1:/300\500/300\

http://myserver/axis-cgi/io/output.cgi?action=1:1000/

http://myserver/axis-cgi/io/input.cgi?check=1,2,3,4