Using a Pan/TIlt/Zoom device

To use a PTZ device, select the port which will connect the device and select the interface
to use. Then click Save. Now click on the menu link for Pan/Tilt/Zoom. The resulting

dialog will now allow you to select the driver for the PTZ you are using. Select the

camera(s) that will be controlled by the device and finally, click the Save button. To make
specific settings for the device, click the Modify... button. See the online help for more

information.

Setting the RS-232 Port for use with a Modem (COM-Port 2 only)

From System Options in the Administration tools, select COM-Port 2 and click the radio
button for Modem. Click Save. To configure the modem, click on the Modem link (also

from the System Options on the main Administration page).

Modem Settings

If you are intending to use your AXIS 2460 over a dial-up modem connection, define the

appropriate communication settings for your modem and click the Save button. Note that
a modem can be used only on COM-port 2.

Communication Settings

Modem Type -

Select a modem from the list of supported V.90 compatible modems in the

drop-down list - selecting Generic if the modem you want to use does not appear in the

list.

Note:

Although most external modems are known to work well with the AXIS 2460,

only the modems listed in the drop-down list have been fully tested.

Disable Incoming Calls -

Check this box if you do not want your modem to answer incoming

calls.

Flow Control -

Synchronizes the connected modems. Hardware flow control is accomplished

by enabling the Control to Send (CTS) and Return to Send (RTS) signals for the serial
interface. If using Software control, the modems will still be synchronized, but the flow

control will use XON/XOFF. If using NONE, there will be no synchronization.

Baud Rate (bps) -

Set the baud rate for the connected modem.

Init String -

This defines the Attention Code (AT) command sent when starting the dial-up

connection, to initialize the connected modem. Using the Attention Code ATz (the common

code for initializing most commercial modems), the Network DVR will normally configure

the port settings for the connected modem automatically.