Specifications – Aquacal Pool Pilot 75003 User Manual

Page 10

Advertising
background image

SPECIFICATIONS

4

Specifications

#75003 Pool Pilot Digital Control unit

Input Power

230 Vac

1.5 amps

(Normal input configuration shipped from the factory)

115 Vac

3 amps

(Optional input configuration – jumper wire to convert included)

Dry Contact

5 mA typical Non-factory ORP input circuit (110Vac output require a Relay Kit – PN# 110-ORP)

Chlorine Output

SuperCell Type

Maximum Chlorine Output (# 75003 Control unit set on Cell Power 3)

SC-36

1.28 lbs/day (0.58 kg/day)

SC-48

1.56 lbs/day (0.71 kg/day)

SC-60

1.92 lbs/day (0.88 kg/day)

CC-15

2.50 lbs/day (1.14 kg/day) – Commercial Cell

Manifold Flow Requirements

Minimum Flow Rate

20 gallons per minute (gpm) (76 liters/minute (L/m))

Maximum Flow Rate

100 gallons per minute (gpm) (379 liters/minute (L/m))

Maximum Pressure

85 psi (as tested by NSF)

Pump/Auxiliary Relay Output

Voltage Input

Amps / HP max

115 Vac

30 amps / 1 HP

230 Vac

30 amps / 2.5 HP

Agency Approvals

• ETL tested to conform to the following UL specifications:

o

UL1081 - Standard for Safety for Swimming Pool Pumps, Filters and Chlorinators

o

UL 1563 - Standard for Safety for Electric Spas, Equipment Assemblies, and Associated Equipment.

• CAN/CSA-E335-1 - Safety of Household and Similar Electrical Appliances

#75001 Pool Pilot Pool Chemistry Control unit

pH Acid Feed Pump and Tank AC Input Power

#75004 120

Vac

1.7

amps

#75005 220

Vac

0.9 amps

#75006 230

Vac

0.9

amps

#75007 250

Vac

0.9

amps

#75008 Auxiliary Relay Kit

115 / 230 Vac Relay

30 amps max

Low Voltage Input Power

PCC Communication

Factory Low Voltage Interface Cable provided with #75001

#75008 pH Auxiliary Relay Kit (Optional) Dedicated Factory Low Voltage Terminal

Flow Cell

Flow Sensor

Fail – Safe status

Maximum working pressure

50 psi

Advertising