Installation, Electronic controller installation – Aquacal Pool Pilot 75003 User Manual

Page 30

Advertising
background image

INSTALLATION

24

Electronic Controller Installation

(Turn off power before making any electrical connections)

Connecting to an Electronic Controller

An Electronic Control System (Jandy® AquaLink RS (version I, K or L), Polaris® EOS, or Pentair IntelliTouch®) may be
connected to the external RS-485 or the internal connector (marked TB1 on the lower Circuit Board) using a 4-wire cable (Jandy
JDY-4278 or equivalent). Program “Select Remote” to match the Electronic Control System, see pg. 35.























On the Pool Pilot Digital:

Pool Pilot

External RS-485 Internal Connection

Jandy Polaris Pentair

# 1

# 1 (+ 9 V)

Red

Pin #4

Red

# 2

# 2 (+ DATA)

Black

Pin #1

Yellow

# 3

# 3 (- DATA)

Yellow

Pin #2

Green

# 4

# 4 (GND)

Green

Pin #3

Black

Jandy® Controller:

Connect to the red
4-pin connector on
the rear of the Jandy
circuit board,
matching the color
code in the chart
below. Connect in
parallel to the
existing wires.

Polaris®

Controller:

Connect to the
4-pin removable
connector on the
command center
board, matching
the color code in
the chart below.

Pentair Controller:

Connect to any of
the IntelliTouch®
COMM ports and
match to the color
code in the chart
below.

Electronic Controller Terminals on Circuit Board

# 838 PCB

TB1

#1

#2

#3 #4

Electronic Controller

Terminal

#75003 Digital Control Panel Base Plate

Electronic Controller
External RS-485

Low Voltage

Terminal Access Port

RS-485 wire harness

#4 #3 #2 #1

External RS-485 Terminal
on Digital Base Plate

Advertising