INSTALLATION

15

Digital Control Panel Base Plate

Ground Lug Cell Cord Connector

Tri-sensor
assembly
connector

Low voltage wiring

Connecting the SuperCell Cable

1. The SuperCell cable connector is keyed and must be aligned to connect properly.

Line up the cell cord and plug into the cell cord connector, located on the bottom
right of the Pool Pilot Digital base plate.

2. The other end of the SuperCell cable may have a red weather plug located in one

of the holes. The SuperCell will have either 2 or 3 electrical terminals

• If the SuperCell has 3 electrical contact terminals then the red weather plug

should be removed and discarded.

• Align the cable and terminals and connect them together.

• If the SuperCell has 2 electrical contact terminals, then the red weather plug

will seal the unused contact in the cable. Position the SuperCell plug so
that the two open holes align with the two mating terminals and connect
them together.

Connecting the Tri-Sensor Cable

The Tri-Sensor Cable is 12 feet (3.4m) long and connects the Tri-Sensor Assembly to the
Pool Pilot Digital. Both ends are keyed and must be aligned to connect properly.

• Connect the white 6-pin connector to the mating plug located on the base of the

Pool Pilot Digital.

• Remove the black dust cap that covers the electrical connector on the Tri-Sensor

Assembly located near the top of the Manifold Assembly.

• Carefully align the black 6-pin connector to the mating plug

located on the Tri-Sensor Assembly. The cable
connector has a slot that will align with the slot on the
mating plug. (The slot on the plug is aligned with the
Tri-Sensor Directional Flow Indicator.) Do NOT force!

• Carefully slide the connector into the mating plug.

Twist the cable connector locking-ring to secure the
connector to the Tri-Sensor.



!Warning


The pins in the Tri-Sensor plug will be permanently damaged, requiring Tri-Sensor replacement, if
the connector is forced on or not aligned properly during insertion. DO NOT FORCE!

Directional Flow
Indicator

Dust
Cap

Plug key

Tri-Sensor

Cable

Tri-Sensor

Cable

SuperCell

Cable