Installation, What is included, Digital controller – Aquacal Pool Pilot 75003 User Manual

Page 15: What is not included

Advertising
background image

INSTALLATION

9

Before Installing the # 75003 Pool Pilot Digital System

• Determine that everything needed for installation is on hand

• Determine where the Manifold Assembly will be plumbed

• Find a suitable mounting location for the Control Unit within proper cord length to the manifold

• Plan cord runs for SuperCell Cable and Tri-Sensor Cable

• For optional TC or pH control systems, plan for flow cell water feed tubes and acid feed tube and electrical connections

• Plan wire runs and wiring connections for source power and optional connections if any;

o

Determine where input power for the Pool Pilot will originate

ƒ directly from a circuit breaker

ƒ from an external Timer or
ƒ from an electronic controller

o

Determine whether the input voltage for the Pool Pilot is 230Vac (factory configured) or 115Vac

o

Determine whether the Pool Pilot will be used to control a single speed pump or a dual speed pump

o

Determine whether the Pool Pilot will be controlled by an ORP controller (or TCC Option)

o

Determine whether the Pool Pilot will be controlled by an Electronic Controller system.

What is included?

Although the manifold assembly may be sold separately, both a manifold and a Pool Pilot Digital Control unit are required for a
complete installation and start-up. The standard cell/manifold assembly is available with the following cells: SC-36, SC-48, SC-
60 (residential cells), or the CC-15 (commercial cell). Before attempting the installation, check that the following items have
been included with the Pool Pilot Pool Pilot Digital Control unit:

DIGITAL

CONTROLLER

Quantity Item

Description

1

# 75003 Pool Pilot Digital Control Unit

AC jumper for 115 Vac configuration

1 Tri-Sensor

Cable

1 SuperCell

Cable

1 Mounting

Template

4 Plastic

Anchors

4 Mounting

Screws

*2

68mm x 2” metric adapters (#19059)

* European Systems only

What is not included

Some of the additional equipment that may be needed to complete the installation:


For any installation

• Appropriate gauge electrical wire

• ½”liquidtite (non-metallic flex) conduit

• ½” conduit connector for service to the Pool Pilot

• Drill

• ¼” masonry drill bit


For installations using optional equipment

• Appropriate gauge electrical wire

• ½” liquidtite (non-metallic flex) conduit

• ½” conduit connector for filter pump

• Cable for connection for ORP interface (PN # 315-AC)

• 4-Conductor cable for connection to Electronic Controller option

Pool Pilot is to be wired to the same location as the main filter pump
so that it only activated when the pump is energized.

Digital Time clock is used to control the main pump
or pump is also running off the breaker

CHECK
SYSTE

M

BOOST MENU SELECT PUMP

MOUNTING

TEMPLATE



Drill (4) ¼

cations.



Drill o

Sean Assam