PROGRAMMING AND OPERATION

36

Total Control Menus

(System configuration must indicate Total Control configuration and is automatically

detected when the electrical connections are made between the #75003 and #75001 systems)

Set pH overfeed (Range: No pH overfeed - 120 minutes in 5 minute increments) (Used to stop the chlorine and acid feed if the pH
set point is not reached in the user programmed time.)

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “pH overfeed” is displayed, then press SELECT (No pH overfeed is the factory setting).

3. Press

∆ or ∇ to the desired overfeed time setting, then press SELECT.

4. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

Set pH min (Used to set the lower limit of pH adjustment before a warning message is displayed)

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Set pH min” is displayed, then press SELECT (6.5 is the factory setting).

3. Press

∆ or ∇ to the desired pH min setting, then press SELECT.

4. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

Set pH max (Used to set the upper limit of pH adjustment before a warning message is displayed)

Note: For safety reasons, acid will not feed when measured above the programmed pH max.

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Set pH max” is displayed, then press SELECT (8.0 is the factory setting).

3. Press

∆ or ∇ to the desired pH max setting, then press SELECT.

4. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

Calibrate pH (Used to match the pH display of the Digital to the results of a reliable pH test kit)

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Calibrate pH” is displayed, then press SELECT (the pH sensor measurement will be displayed).

3. Press

∆ or ∇ to match a reliable pH test result, then press SELECT.

4. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

Enable / Disable ORP (Used to temporarily enable or disable the ORP control system, thus disabling the chlorine generation)

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Enable ORP or Disable ORP” is displayed, then press SELECT.

• if “Enable ORP” then the ORP sensor is disabled, press SELECT to enable the ORP sensor.

• if “Disable ORP” then the ORP sensor is enabled, press SELECT to disable the ORP sensor.

3. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

Set ORP overfeed (Range: No ORP overfeed - 120 minutes in 5 minute increments) (Used to stop the chlorine and acid feed if
the ORP set point is not reached in the user programmed time.)

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “ORP overfeed” is displayed, then press SELECT (No ORP overfeed is the factory setting).

3. Press

∆ or ∇ to the desired overfeed time setting, then press SELECT.

4. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.