Programming and operation, Menus – Aquacal Pool Pilot 75003 User Manual

Page 39

Advertising
background image

PROGRAMMING AND OPERATION

33

MENUS

(For the Installer Menu, press and hold SELECT button for approximately 13 seconds to access this feature)

Programming the SuperCell to activate a Force reverse cycle for testing (Used to verify if the Digital unit is reversing polarity
(self cleaning)).

There is a 30 second delay before reversing takes place after you End menu mode.

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Force reverse” is displayed, then press SELECT.

3. “Cell reversing” will display temporarily.
4. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

5. The “

.

”(period) on the end of 2

nd

line of the display will either appear or disappear based on its previous state to indicate

that the cell has reversed.

Programming the SuperCell reverse time (self cleaning) cycle

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Set reverse time” is displayed then press SELECT (4 hours is the factory setting).

3. Press

∆ or ∇ until the desired cycle time (2, 4, 8, or 16 hours) is displayed, then press SELECT.

Warning: Shorter cycle times can reduce the SuperCell life and should only be changed due to uncontrollable
scale formation on the SuperCell.

4. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

Programming the unit to enable or disable a remote electronic control system by the Jandy, Polaris or Pentair electronic control
systems
(Used only when wired to operate through the electronic control system)

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Enable remote or Disable remote” is displayed

• if “Enable remote” then the electronic controller is disabled, press SELECT to enable the electronic controller.

• if “Disable remote” then the electronic controller is enabled, press SELECT to disable the electronic controller.

3. Press

∆ or ∇ until “End menu mode” is displayed, then press SELECT.

Replace Cell (Used to reset the ampere-hour counter after a cell is replaced)

1. Press MENU, press

∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Replace Cell” is displayed, then press and hold SELECT for 13 seconds. “Amp-hours = zero” will

be momentarily displayed.

3. Press

∆ or ∇ until “End menu mode” is displayed then press SELECT.

Programming the unit to Set prime protect (Range: No prime protect, 1-, 2-, 4-, 8- minutes) (used to provide protection against
potential damage of a one-speed pump by loss of prime and will shut down pump, chlorine, and acid feed operation if there is a
loss of flow for a user programmed time period – “No prime protect” is the factory setting)

Caution: Damage to equipment caused by a loss of prime to the pump system is not covered under warranty. The prime
protection feature is designed to assist in preventing damage. However, conditions beyond the control of the Digital Control
System may still allow damage to occur!

1. Press MENU, press

∆ or ∇ until “Maintenance menu” or “Installer menu” is displayed, then press SELECT.

2. Press

∆ or ∇ until “Set prime protect” is displayed, then press SELECT.

3. Press

∆ or ∇ to adjust to the desired length of time before prime protect activates, then press SELECT.

4. Press

∆ or ∇ until “End menu mode” is displayed then press SELECT.

Advertising