PROGRAMMING AND OPERATION

30

Operation of Buttons

(Continued)

Pump Button

(This button is not active if the Set Relay 1 is programmed for “Acid Pump” or “Relay not used”. If the Pump button is pressed
when programmed for one of these modes, ”Acid Pump” or ”Relay 1 not used” will display, then revert back to the normal
display.)
Pump Button – One-speed pump control - The Pool Pilot must be wired to control the main circulation pump and programmed for
a One-speed pump for this feature to be active (see pg. 34).

With “PUMP ON”, to turn “PUMP OFF”;

1. Press PUMP.
2. “

∇ - Stop Pump” will be displayed. Press ∇.

3. “pump off” will be displayed.


With “PUMP OFF”, to turn “PUMP OFF FOR SERVICE” -
(This mode disables Pump operation indefinitely, until manually enabled. Boost and Pump program modes will not enable
pump.)

1. Display indicates “pump off”.
2. Press PUMP.
3. Press

∇ - Maintenance

4. “PUMP OFF FOR SERVICE” and a Red CHECK SYSTEM light will now be displayed.


With “PUMP OFF FOR SERVICE”, to terminate maintenance mode and return to “PUMP OFF”.

1. Press PUMP.
2. Press

∆ - End Maint.

3. Pump will be in the “pump off” status.


With “PUMP OFF”, to turn “PUMP ON”.

1. Press PUMP.
2. Press

∆ - Start Pump

3. The pump will run until the pump program reaches the next scheduled turn off time

Pump Button – Two-speed pump control - The Pool Pilot must be wired to control a two-speed main circulation pump and
programmed for Two-speed pump for this feature to be active. The Pool Pilot cannot turn off the pump, and can only change
pump speeds, between high and low (See pg. 34).

With pump on “HIGH SPEED”, to switch to “LOW SPEED”.

1. Press PUMP.
2. Press

∇ - Low Speed

3. Pump will switch to low speed.

With pump on “LOW SPEED”, to switch to “HIGH SPEED”.

1. Press PUMP.
2. Press

∆ - High Speed

3. Pump will switch to high speed.