Ip401 compact office wall mounting – Avaya IP OFFICE 40DHB0002USCL User Manual

Page 43

Advertising
background image

Installing a New System

IP401 Compact Office Wall Mounting - Page 43

IP401 Compact Office Wall Mounting

Bath variants of the IP401 Compact Office can be wall mounted. Four retaining slots (item n below)
enable the IP401 unit to be mounted in any one of three positions (two horizontal and one vertical) by

using two No. 8 Panhead screws. A Z-bracket (item o below, supplied with unit) is used to retain the
IP401 unit in position.
Cautions: 1. The Z-bracket must not be used as the sole wall mounting fixture.

2. The weight of the IP401 unit must be held by the two No 8 Panhead screws located

into the retaining slots.

3. When mounted vertically, the air vents (on the rear panel of the IP401 unit) must be

on the top surface. E.g. item o below must be fitted above the unit.

Procedure:
1. Drill two holes 16cm apart (horizontally or vertically – see Caution 3 above).

Using suitable wall fixings (wall plugs), insert two No.8, Panhead screws (25mm long min. - not

supplied) into wall leaving approximately 1cm proud of wall.

2. Fit the Z-bracket (item o below) onto the base of the unit using the M3 Plastite self tapping screw

supplied.

3. Slide the IP401 Compact Office unit onto the two screws, locating them into the two retaining slots

(item n below).

4. Mark the position of the retaining screw (No. 8 Panhead or similar – not supplied) that is to be

used through the slot of the Z-bracket .

5. Remove the unit from the wall and, using suitable wall fixings, drill a hole for the Z-bracket

retaining screw.

6. Re-position the IP401 compact Office unit and secure with a No. 8 Panhead (or similar) through

the slot of the Z-bracket.

IP Office Installation Manual

Installing a New System - Page 43

40DHB0002USCL – Issue 7 (09/25/2002)

IP401 Compact Office Wall Mounting

Advertising