Telephone converter cables, Rj45 - compatible converter, Rj11/45 adapter – Avaya IP OFFICE 40DHB0002USCL User Manual

Page 65: Out of building installation

Advertising
background image

Technical Data

Cables - Page 65

Telephone Converter Cables

The following diagrams show the pin-outs of various Structured Cabling Telephone Converters. The

first two telephone converters shown provide the required conversion allowing correct operation of

the attached telephone.
Each telephone port on the Phone modules acts as a Master socket, thus only Slave Telephone

Converters are required.

RJ45 - Compatible Converter

Telephone

Converter Cable

Structured Wiring/

Unity Phone

BT New Plan

Socket

RJ11

Plug

RJ45

socket

Latch

1

7
6 Bell
5 B
4 A (Bell return)
3
2

2
3
4
5
6

7
6
5
4
3
2
1

RJ11/45 Adapter

RJ45 or RJ11 plug

BT Newplan Socke

RJ11 Pin Number

RJ45 Pin Number

BT Newplan Socket Pin Number

3 4

3

4 5

4


Other connections are not relevant.

BT Newplan socket connections may be reversed as polarity is not important.

This adapter may be used with DT telephones fitted with BT Newplan plugs.

Out of Building Installation

In the USA only, installation of telephone and/or other standard (tip/ring) devices in another building

requires the following:
• In-Range-Out-Of-Building (IROB) protectors, to protect the control unit and device from electrical

surges, must be fitted as follows:
- System telephone : two IROB protectors
- Standard telephone : two IROB protectors plus one carbon block protector.

Install the IROBs as per the instructions supplied with the IROB. Three versions are available as

follows :
- 146C - Trunks - SAP code 407228923
- 146D - Two-wire - SAP code 407568146
- 146E - TDL - SAP code 407568161

• Installation of a Contact Closure Adjunct controlled device outside the building requires a 146G

Surge Protector – SCL/8 to protect the control unit from electrical surges.

Installation Manual

Technical Data - Page 65

IP Office

40DHB0002USCL – Issue 7 (09/25/2002)