Trunk line from NHX-80X to sub stations should be
Aiphone specified cable or UL Listed cable
(3 twisted pair).

• If 4-zone lamp is included, use 4 twisted pairs.
• In a zone with more than 10 stations, additional

subs must be wired in a separate trunk line, but
the ZL line may be extended from any sub on the
previous trunk line.

Permitted wiring distance to Sub stations;

165' with 22AWG, 50m with 0.65mm (from CCU to
farthest sub).

Max. 330', 100m total distance per trunkage line
(includes length of trunk line, plus wire length
T-tapped from junction point to each patient station
in the trunk line).

WIRING DIAGRAMS

3. NHX-80X CCU to Sub stations

Take G terminal to earth ground on 2
power supplies.

NHX-80X

NH-1SA/A
NH-1SA
NH-2SA/A
NH-2SA or
NHR-3TS

NH-1SA/A
NH-1SA
NH-2SA/A
NH-2SA or
NHR-3TS

NH-1SA/A
NH-1SA
NH-2SA/A
NH-2SA or
NHR-3TS

PS24

PS24

Power supply: PS-24E or PS-2420, DC24V, 2A

+

G

B+
B–

PS24

+

G

A+
A–

Z4 Z2

81
82
83
84
85
86

41
42
43
44
45
46

To Subs block 8

Z3

CCU

Z1

ZL

51
52
53
54
55
56

11
12
13
14
15
16

1
2
3
4
5
6

To Subs block 5

To Subs block 4

71
72
73
74
75
76

31
32
33
34
35
36

To Subs block 7

To Subs block 3

ZL terminal may be connected
to Z1 ~ Z4 terminal in NHX-80X,
depending on zone of patient station.

61
62
63
64
65
66

21
22
23
24
25
26

To Subs block 6

To Subs block 2

To Subs block 1

See page 16 for
actual terminal
block layout

ZL

1
2
3
4
5
6

ZL

1
2
3
4
5
6

ZL

1
2
3
4
5
6

ZL

1
2
3
4
5
6

ZL

1
2
3
4
5
6

Bedside Sub or Bathroom sub stations

Each pair:
polarized

CN1 Brown
Red
Orange
Yellow
Green
Blue
CN2 Purple

CN1
as above

CN2
as above

Do not connect two power supplies in parallel.

CN1

CN2

PS24

PS24

NHX-80X

Sub stations NH-1SA/A, NH-1SA,
NH-2SA/A, NH-2SA or NHR-3TS

:PS-24E or

PS-2420

6(3P)

1

2

3

9

10

120V AC

PS24

Trunk 1

Trunk 2
Trunk 3

Trunk 8

Advertising