Technical precautions – Aiphone 83873900 0602 E User Manual

Page 30

Advertising
background image

– 30 –

Type of calling

Call tone

Light

At NHX-50M Master station
• Receiving

Routine call

Single chime, every 6 sec.

Blinking, every 2 sec.

Bathroom call (urgent)

Single chime, every 2 sec.

Double blinking, every 1.8 sec.

Cord-out trouble call

Single chime, every 0.5 sec.

Blinking fast, every 0.4 sec.

• Line-off trouble

Bedside sub from Trunk

Slow buzzer, intermittent

Lit 0.2 sec., every 2 sec.

Duty station from NHX-80X

Faster buzzer, intermittent

No light

• While talking

Call tone (as above)

Call-in LED steadily lit

At NH-1SA/A, NH-1SA, NH-2SA/A or NH-2SA Bedside Sub station
• Placing

Routine call

CALL steadily lit

Bathroom call (urgent)

Not lit
CALL lit on Pullcord switch

Cord-out trouble call

CALL steadily lit.

• While talking

CALL is off, and TALK is on.

• When master calls in

Pre-tone

TALK is on

At NHR-4A Room Corridor lamp (white/red)
• When Sub placed a call Routine call

White steadily lit

Bathroom call (urgent)

Red blinking

Cord-out trouble call

White blinking

While talking

Not lit

At NHR-3A-4 Zone light
• When Sub placed

Routine call

1 ~ 4 lamp turns on for any call from

Urgent call

Bedside sub or NHR-3TS.

Cord-out trouble call

At NHR-3TS sub station (w/corridor lamp) in Common area or Hallway
Placing

Bathroom call (urgent)

Red blinking on NHR-3TS

Staff call (urgent)

White blinking on NHR-3TS

At NHR-SP Duty station
• When Master received Routine call

Single chime, every 6 sec.

CALL blinking, every 2 sec.

Urgent call

Single chime, every 2 sec.

CALL double blinking, every 1.8 sec.

Cord-out trouble call

Single chime, every 0.5 sec.

CALL blinking fast,every 0.4 sec.

While Master talking

Not lit

Calling from NHX-50M
When NHX-50M has called a bedside Sub station, no light turns on on the corridor lamp, zone light and sub station
except TALK LED lit green on the sub station.

Call tone & light annunciation

(*) Sound & LED time is approximate.

5. OPERATIONS on NHX-50M

6

6

6

6

TECHNICAL PRECAUTIONS

Temperatures

NHX-80X and NHX-50M are rated to operate at
temperatures 10˚C~49˚C(50˚F~120˚F).

Duty Station Operation

At NHR-SP, sub station call-in is annunciated by
tone & LED, which are the same as on
NHX-50M.
• The TONE-OFF button silences tone, but CALL

LED remains lit. When the NHX-50M begins
communication, both tone and LED are
deactivated.

• 90 seconds after the call tone is muted, it will ring

again. Press TONE-OFF button, and it will no
longer ring (tone will resume when another sub
calls).

Call Holding

Every Routine call is held electronically at bedside
sub station, and will be automatically connected
when handset is lifted or TALK button is pressed at
the NHX-50M. To reset the call, press CANCEL
button on the Sub station. When a Bathroom call &
Cord-out trouble call is activated, the LED will
remain on even after the NHX-50M has answered.
The call must be reset at the calling site.

Advertising