Multi-station patient room applications – Aiphone 83873900 0602 E User Manual

Page 23

Advertising
background image

– 23 –

WIRING DIAGRAMS

Multi-Station Patient Room Applications

2. Max. 12 bed application covered by six NH-2SA/A sub stations

with or without a common bathroom pullcord

(*1) Terminal Z1 for lighting Lamp 1 in NHR-3A-4.
(*2) NHR-7A may be wired to any sub station convenient.

Terminal RL is wired only on the sub station which
NHR-7A is connected to.

(*3) Remove the red cap on a lamp inside.

Notes:
1. In the above example, NHR-4A 2 is required only

when NHR-7A, bathroom pullcord is installed in
single and common bathroom.

2. Bedside sub stations Models: NH-1SA and NH-2SA

CANNOT be used in multiple bed patient rooms.

NH-1SA/A
NH-2SA/A
#1

#2

#3

3P

2

3P(or 4P)

3 or 4

3

3P

2

#5

#4

#6

3P

2

3P

2

2 white lamps

NHR-4A

(*) One red lamp

NHR-4A

NHX-80X
CCU

NHR-7A

Left row

Right row

(common

bathroom)

Subs trunk line 1

(*) Requried only when NHR-7A bathroom pullcord is used.

1
2
3
4
5
6

WL

RL

E

TC

TL

E

ZL

LC

Z1

11
12
13
14
15
16

NHR-4A 1

NHR-4A 2

Brown
Orange

Orange

Red

Red

Orange

Purple

Brown

Orange

Purple

Gray

Brown

Orange

Purple

Gray

Brown

Orange

Purple

Gray

Brown

Orange

Purple

Gray

Brown

Orange

Purple

Gray

Yellow

Green

Blue

Blue

(*1)

CN1

CN2

To Subs
block 1

Each pair: polarized

1 red lamp

(*3)
2 white
lamps

1
2
3
4
5
6

WL

RL

E

TC

TL

E

ZL

LC

1
2
3
4
5
6

WL

RL

E

TC

TL

E

ZL

LC

1
2
3
4
5
6

WL

RL

E

TC

TL

E

ZL

LC

1
2
3
4
5
6

WL

RL

E

TC

TL

E

ZL

LC

1
2
3
4
5
6

WL

RL

E

TC

TL

E

ZL

LC

#1

#2

#3

#4

#5

#6

Right row of Bedside Subs

Left row of Bedside Subs

NHR-7A

Advertising