Bathroom call sub station: nhr-3ts, Wiring diagrams – Aiphone 83873900 0602 E User Manual

Page 21

Advertising
background image

– 21 –

5. Bathroom call sub station: NHR-3TS

WIRING DIAGRAMS

4. Bedside sub stations w/Corridor lamp & Bathroom Pullcord

Take G terminal to earth ground on 2
PS-24E or PS-2420 power supplies.

PS24

NHX-80X

Bedside Sub stations: NH-1SA/A, NH-1SA,

NH-2SA/A or NH-2SA

Staff Call

6(3P)

1

3

3

120V AC

PS24

Trunk 1

Trunk 8

Men

Women

2

9

Bathroom Call

10

3

3

3

3

3

NHR-4A

NHR-4A

NHR-7A

NHR-7A

NHR-7A

NHR-7A

NHR-3TS

NHR-3TS

NHX-80X

CCU

To Subs

block 1

ZL

Z1

1
2
3
4
5
6

11
12
13
14
15
16

(any zone)

Bedside Sub stations: NH-1SA/A, NH-1SA,

NH-2SA/A or NH-2SA

1

2

Each pair:
polarized

ZL

1
2
3
4
5
6

Corridor lamp

Bathroom pullcord
(mechanical lock)

Master-CALL LED

E

NHR-4A

NHR-7A

CN1

CN2

Purple

Purple

Brown
Red
Orange

Blue

Yellow

Green

WL

RL

E

TC

TL

White

Red

Brown

Green

Yellow

Blue

Blue

Green

Yellow

Blue

Orange

Red

LED

CN2

CN1

Brown

Red

Orange

Orange

LC terminal is not used (not shown).

NHX-80X

NHR-3TS

NHR-7A

NHR-7A

NHR-7A

NHR-7A

CCU

As many pullcords needed
can be connected to NHR-3TS.

(*1) On NHR-3TS for staff call, remove

the red cap on lamp inside.
Urgent staff call must be white
blinking light.

(*2) LC terminal is not used (not shown).

Urgent call switch
mechanical lock

TC1

TL1

E

TC2

TL2

ZL

Z1

1
2
3
4
5
6

11
12
13
14
15
16

(any zone)

9

Each pair:
polarized

1
2
3
4
5
6

Master-CALL
lamp

Master-
CALL
LED

(*1)white

Staff Call (corridor)

Bathroom call (common area)

Men

Women

NHR-3TS

10

red

red

TC1

TL1

E

TC2

TL2

ZL

CN1

CN2

CN1

CN2

LED

NHR-7A

LED

LED

Blue

Green

Brown

Red

Orange

Yellow

Green

Blue

Purple

Blue

Yellow

Brown

Yellow
Green
Blue

Purple

Red
Orange

Yellow

Green

Blue

Blue

Yellow

Green

Green

Blue

Yellow

Blue

Blue

Blue

Green

Yellow

Blue

Blue

LED

LED

Advertising