Installation, Plumbing connections – Blodgett BC-20G User Manual

Page 10

Advertising
background image

6

Installation

Plumbing Connections

WaTER COnnECTIOn
NOTE: Hot water maximizes steam production but is not

required. Cold water may be supplied to both in-

lets if hot water is not available.

Connect the appliance to quality cold water via a pressure

hose with 3/4” (1/9 cm) couplings. Cold water is connect-

ed to the left solenoid/pressure regulator as viewed from

the rear of the oven. Hot water connection, right solenoid/

pressure regulator, to the boiler is recommended. A shut

off valve must be provided adjacent to the oven.
NOTE: Hot water must not be applied to the cold water

inlet.

1/2” Appliance Hose with 3/4”

Hose Fittings

Figure 1

WaRnInG!!

The use of poor quality water will invalidate

your warranty.

This product must be installed by a licensed Plumber or

Gas Fitter when installed within the Commonwealth of

Massachusetts.

dRaIn COnnECTIOn
A 2” (5 cm) copper pipe with standard drain pitch must

be run to an open drain or connected to a standpipe

equipped with a vent.
NOTE: The waste water can also be directed to a nearby

floor drain. Flexible hose which allows trapped

water to accumulate in sagged runs must be

avoided.

1. Find the drain connection on the lower rear of the unit.
2. Loosen the coupling clamps. Attach a 2” (5 cm) cop-

per drain pipe to the drain connection. Retighten the

coupling clamps.

NOTE: The open end of the drain should be installed

facing the floor. Copper line, used for installation

to an open drain or floor sink, must be supplied

by the installer.

Use of a trap inline will cause

drain backup.

2” Drain

Customer

Supplied

To Drain

Oven Drain

Figure 2

Specific water/drain connection for City of Los Angeles
1. Each drain line from the appliance shall be routed

without dips or sags to terminate above the flood level

rim of an approved indirect waste receptor.

2. The appliance shall be installed in accordance with

the manufacturer’s printed instructions and the LAPC

and LAMC, 1999 editions.

3. A backflow protection device may be required by lo-

cal codes. If so, install on the potable water system

directly ahead of the appliance. The backflow protec-

tion device shall be any of the following: an approved

pressure type vacuum breaker installed at least 12”

above the highest point of use, a double check valve

backflow preventer or a reduced pressure principal

backflow preventer.