Installation, Electrical connections – Blodgett BC-20G User Manual

Page 11

Advertising
background image

7

Installation

Electrical Connections

Before making any electrical connections to these units,

check that the power supply is adequate for the voltage,

amperage, and phase requirements stated on the rating

name plate mounted on the right side of the unit.
Wiring diagrams are located on the inside of the remov-

able side panel.
NOTE: Disconnect the Power Supply to the unit Before

Servicing!

U.S. and Canadian installation
All units, when installed, must be electrically grounded

in accordance with local codes or in the absence of lo-

cal codes, with the National Electrical Code, ANSI/NFPA

70-Latest Edition and/or Canadian Electrical Code CSA

C22.1 as applicable.
General Export Installations
Installation must conform with Local and National instal-

lation standards. Local installation codes and/or require-

ments may vary. If you have any questions regarding the

proper installation and/or operation of your unit, please

contact your local distributor. If you do not have a local

distributor, please call Blodgett Combi at 0011-802-658-

6600.

WaRnInG!!

Improper electrical installation will invalidate

your warranty.

BC-20G only
U.S. and Canadian Installations
A power cord (115V or 230V) is supplied with a plug at-

tached. Plug the power cord into the desired receptacle.
This oven model uses a variable frequency inverter

drive. Appliances that use variable frequency inverter

drives produce high frequency noise and require filters

and shielded motor cabling. This causes higher leakage

current toward Earth Ground. Especially, at the moment

of switching ON this can cause an inadvertent trip of the

appliance’s ground fault interrupter (GFCI). Some GF-

CIs are more sensitive than others. Blodgett has quali-

fied the Pass and Seymour brand, part number 2095,

20 A, 125 VAC, 60 Hz, specification grade GFCI duplex

receptacle as being immune to the variable frequency

inverter drive’s noise. Blodgett recommends using this

specific GFCI for this model oven.

WaRnInG!!

If the supply cord is damaged, it must be re-

placed by a special cord or assembly available

from the manufacturer or its service agent.

Advertising
This manual is related to the following products: