Installation, Owner’s responsibilities – Blodgett BC-20G User Manual

Page 6

Advertising
background image

2

Installation

Owner’s Responsibilities

PLUMBInG SPECIFICaTIOnS - BC-20E & BC-20G

WaTER
Water pressure

40 PSI min/116 PSI max

Water connection

3/4” Hose Fitting, 3/8” ID hose minimum

Water pressure regulator setting

35 PSI Preset

Minimum requirements

TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: 0 ppm
pH: 7.0-8.5

dRaInaGE
Drain type

Atmospheric Vented Drain

Drain connection

2” O.D.

Maximum water drain temperature 140ºF (60ºC)

GaS RaTInGS - BC-20G

Gas Input
Steam

90,000 BTU/HR

Hot Air

125,000 BTU/HR

Inlet Pressure to the Unit
Natural Gas

5-14” WC (1.24-3.48 kPa)

Propane

11-14” WC (2.73-3.48 kPa)

Pressure at the Manifold
Natural Gas

3.5” WC (.87 kPa)

Propane

10” WC (2.49 kPa)

3/4” MNPT connector for all US and Canadian installations

1. Oven(s) are uncrated and put in place.
2. The owner/operator must have the following plumb-

ing, gas and electrical requirements met and installed.

NOTE: Refer to the Utility Connection information

provided.

WaRnInG!!

Improper installation, adjustment, alteration

service or maintenance can cause property

damage, injury or death. Read the installa-

tion, operation and maintenance instruction

thoroughly before installing or servicing this

equipment.

Advertising
This manual is related to the following products: