Installation, Gas connection – Blodgett BC-20G User Manual

Page 13

Advertising
background image

9

Installation

Gas Connection

PRESSURE REGULaTIOn and TESTInG
The gas pressure to the appliance must be rated for each

appliance while the burners are on. A sufficient gas pres-

sure must be present at the inlet to satisfy these condi-

tions. Refer to the table below for correct gas pressure.
Each appliance has been adjusted at the factory to oper-

ate with the type of gas specified on the rating plate at-

tached to the right side of the appliance.
Each oven is supplied with a regulator to maintain the

proper gas pressure. The regulator is essential to the

proper operation of the oven and should not be removed.
DO NOT INSTALL AN ADDITIONAL REGULATOR

WHERE THE UNIT CONNECTS TO THE GAS SUPPLY

UNLESS THE INLET PRESSURE IS GREATER THAN

14” W.C. (1/2 PSI) (37mbar).
The oven and its individual shutoff valve must be discon-

nected from the gas supply piping system during any

pressure testing of that system at test pressures in ex-

cess of 1/2 psig (3.45kPa).
The oven must be isolated from the gas supply piping

system by closing its individual manual shutoff valve dur-

ing any pressure testing of the gas piping system at test

pressures equal or less than 1/2 psig (3.45kPa).

Prior to connecting the appliance, gas lines should be

thoroughly purged of all metal filings, shavings, pipe

dope, and other debris. After connection, the appliance

must be checked for correct gas pressure.
U.S. and Canadian Installations
Installation must conform with local codes, or in the ab-

sence of local codes, with the National Fuel Gas Code,

NFPA54/ANSI Z223.1-Latest Edition, the Natural Gas

and Propane Installation Code CAN/CSA-B149.1.
General Export Installations
Installation must conform with Local and National instal-

lation standards. Local installation codes and/or require-

ments may vary. If you have any questions regarding the

proper installation and/or operation of your appliance,

please contact your local distributor. If you do not have a

local distributor, please call Blodgett Combi at 0011-802-

658-6600.

GaS PRESSURE

Gas Type

Inlet Pressure

Orifice Size at Sea Level

Manifold Pressure

Hot Air

Steam

Hot Air

Steam

U.S. and Canadian Installations

Natural

5-14” W.C.

1/16”(.0625”) dia

#58 .042” dia

3.5” W.C.

3.5” W.C.

Propane

11-14” W.C.

#62 .0380” dia

#70 .0280” dia

10” W.C.

10” W.C.

Advertising
This manual is related to the following products: