An electrical wiring diagram is located in the front access

door of the fryer. The fryer must be installed by a

qualified electrician. This appliance must be branch circuit

protected with proper ampacities, in accordance with the

wiring diagram located in the fryer. The fryer must be

properly grounded in accordance with the National

Electrical Code and applicable local codes. A means to

disconnect the unit must be incorporated into the fixed

wiring in accordance with wiring codes.
Wire size for the main incoming power to the unit must

match the minimum size listed in the specifications

applicable to the specific fryer. For supply connections,

locate the wire size posted on the label located on the

electrical control box cover, behind the service panel or

elsewhere listed in this manual.
Before operating the fryer, check all cable connections in

the electrical connection area for tightness since

connections can loosen during transport.

230V:

To prevent an electrical shock hazard between the

appliance and other appliances or metal parts in close

vicinity, an equalization-bonding stud is provided. An

equalization bonding lead must be connected to this

stud and the other appliances / metal parts to provide

sufficient protection against potential difference. The

terminal is marked with the following symbol.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

E L E C T R I C A L R E Q U I R E M E N T S

ELECTRICAL • ASF-75G

W I T H D E L U X E C O N T R O L

VOLTAGE

PHASE

CYCLE

/

HZ AMPS

K

W

120 (

AGCY

) 1

60

7.2 0.864

230 (

AGCY

) 1

50/60

4.0

0.92

N

N E

E M

M A

A

5-15P

15A-125V Plug

ELECTRICAL • ASF-60G

W I T H D E L U X E C O N T R O L

VOLTAGE

PHASE CYCLE

/

HZ AMPS

K

W

120 (

AGCY

) 1

60

1.2

1.5

230

1

50/60

1.0

2.3

N E M A

5-15P

15A-125V

PLUG

C E E

7 / 7

220-230V

PLUG

C E E

7 / 7

220-230V

PLUG

I N S T A L L A T I O N

Gas Fryer Operation & Care Manual • 11