P R O G R A M M I N G T H E C O N T R O L

Starting with the control in the OFF position, press and hold the “PROGRAM” key

for a period of 5 to 10 seconds.

“Boil”

will always appear as the first item in the display whenever the “PROGRAM” key is initially

pressed. Detailed boil-out instructions are located on

PA G E

12

of this manual.

Press the

DOWN

arrow key to bypass the “Boil” program.

“Boil”

Press the right

arrow key enter the “Boil” program (

S E E PA G E

12)

.

The display will indicate “READY ?”. Press the right

arrow key to

start the boil-out function. The boil-out solution will begin to heat to a
temperature of 195°F (91°C). When the temperature has been reached, the
display will begin a 10 minute countdown.

At the end of the boil-out period, an alarm will sound and the control
will revert to the OFF state.

Boil

NOTE: Before entering this program, make certain the frypot is empty of all oil or shortening.

Close the frypot drain. Carefully follow the manufacturer's mixing directions and fill
the frypot with a mixture of cold water and fryer boil-out solution.

Ready ?

To exit the control programming mode at any time, press and hold t

he LEFT

arrow key

.

Gas Fryer Operation & Care Manual • 28

D E L U X E C O N T R O L O P E R A T I O N

C A U T I O N

DO NOT LEAVE THE FRYER UNATTENDED DURING THE
BOIL-OUT PROCESS. THE FRYER MUST BE
CONTINUOUSLY MONITORED FOR BOIL-OVER
CONDITIONS, PARTICULARLY IN HIGH-ALTITUDE
LOCATIONS. IF BOIL-OVER IS IMMINENT, IMMEDIATELY
TURN THE MASTER POWER SWITCH OFF AND ALLOW
THE SOLUTION TO COOL. WHEN THE SOLUTION HAS
COOLED, RE-ENTER THE BOIL-OUT MODE.