P R O G R A M M I N G T H E C O N T R O L

“LO BAND”

“LO BAND”

provides an alarm notification when the temperature of the

oil is lower than the set-point temperature. The adjustment range is
between 5°F and 100°F (3°C and 56°C) with a factory preset of 21°F (12°C).

Press the Up

or Down

arrow keys to scroll until “LO BAND” appears in the display.

Press the Right

arrow key to enter the program. Display stops flashing. Press the Up

or Down

arrow keys to scroll until the desired number appears in the display. When

the desired setting appears, press the Right

arrow key to accept the selection. Display

flashes. Press the Down

arrow key to advance the control to the next programming

function.

“HI BAND”

“HI BAND”

provides an alarm notification when the temperature of the

oil becomes higher than the set-point temperature. The adjustment range
is between zero and 100°F (38°C) with a factory preset of 25°F (14°C).

Press the Up

or Down

arrow keys to scroll until “HI BAND” appears in the display.

Press the Right

arrow key to enter the program. Display stops flashing. Press the Up

or Down

arrow keys to scroll until the desired number appears in the display. When

the desired setting appears, press the Right

arrow key to accept the selection. Display

flashes. Press the Down

arrow key to advance the control to the next programming

function.

“MELT CT”

The fryer control includes a melt function with ON/OFF pulsed heating cycles for the
purpose of melting solid shortening at a continuous but slower rate to assure full melt-
down. The operator has the ability to control the ON/OFF pulse rate between 00:01 and
00:60 seconds. The factory default is set for 10 seconds (00:10).

Press the Up

or Down

arrow keys to scroll until “MELT CT” appears in the display.

Press the Right

arrow key to enter the program. Display stops flashing. Press the Up

or Down

arrow keys to scroll until the desired time appears in the display. When the

desired setting appears, press the Right

arrow key to accept the selection. Display

flashes. Press the Down

arrow key to advance the control to the next programming

function.

The “PREHEAT BAND” is used to prevent the oil temperature in the frypot from
reaching the actual set-point temperature in order to compensate for temperature override
as the fryer calls for heat. This program feature is set to 10°F (6°C) at the factory.
I t i s s t r o n g l y u r g e d t h a t t h e “ P R E H E AT B A N D ” r e m a i n a t t h i s s e t t i n g .

0 : 1 0

Melt Ct

1 0 °F

Preheat Band

2 5 °F

Hi Band

Hi Temp

“PREHEAT

BAND”

To exit the control programming mode, press and hold t

he LEFT

arrow key

.

Low Temp

2 1 °F

Lo Band

Gas Fryer Operation & Care Manual • 39