EVOLUTION GAS STEAMER

4

Only qualified service technicians/electricians should preform the installation to ensure that all

electrical, gas and safety requirements are met and that all wiring, gas and plumbing installations are

preformed in accordance with all national, state and local codes.

The installation must conform with local codes, or in the absence of local codes, with the National

Fuel Gas Code, ANSA/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1 as

applicable.

The appliance and its individual shutoff must be disconnected from the gas supply piping system

during any pressure testing of that system at test pressures in excess of 1/2 PSI(3.5kPA)

LOCATION AND PLACEMENT

The AccuTemp Evolution gas steamer can be placed on a commercial kitchen counter-top, flush

mounted or installed on a AccuTemp Evolution gas steamer stand. Provisions should be incorporated

in the kitchen to ensure an adequate supply of fresh air for proper combustion and ventilation. See

Fig. 1

LOCATION COMBUSTIBLE

NONCOMBUSTIBLE

SIDES

1”

0”

REAR

2”

0”

EQUIPMENT CLEARANCE

UNPACKING

This appliance was carefully inspected before shipment from the factory. The transportation

company assumes full responsibility for safe delivery to the customer until customer acceptance of

the package. Careful inspection of the packaging and the appliance should be completed before

acceptance from the transportation company.

STEAMER LIFTING

Steamers are heavy enough to require additional manpower or powered assistance when installing or

moving the steamer.

LEVELING

The steamer must be installed in a level condition. An out of level condition may cause erratic opera-

tion and damage to the steamer. Damage of this kind is not covered by the limited warranty. Use a

spirit level resting on the top surface of the steamer to ensure it is level front to back and left to right.

COUNTER TOP INSTALLATION

In a counter top installation the steamer is leveled using the adjusters on the legs of the steamer.

Once this is complete it is required that the supplied (4) rubber foot tips must be installed to keep the

steamer from possibly sliding on the counter top under normal use.

STAND INSTALLATION

If a AccuTemp Evolution Gas Steamer Stand is used ensure the floor is level and place the two lock-

ing casters to the “ON” position.

All AccuTemp Evolution Gas Steamer Stand with casters, shall be made with a connector that com-

plies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or CAN/CGA 6.16

and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use

with Gas Fuel, ANSI Z21.41 or CAN1-6.9.