MP4010-1003

EVOLUTION GAS STEAMER

12

VENTILATION

The steamer produces water vapor along with the extremely hot products of combustion.

Applicable federal, state and/or local plumbing codes will dictate when and if a hood is required.
When installing a gas fired appliance in any location, provisions should be made for adequate make

up air. Additionally the appliance should not be positioned in locations where the appliance is subject

to drafts.

Air Supply

It is necessary that enough room air be allowed to compensate for the amount of air removed by any

ventilation system. All gas appliances require sufficient air to operate
Large objects should not be placed around the appliance which might obstruct air flow. Do not

obstruct the flow of combustion and ventilation air.
Do not permit fans to blow at the appliance, and wherever possible, avoid open windows near to the

sides and back of the appliance. Check wall fans to make sure air cross currents are not created in

the room.

DRAIN LINE CONNECTION –CONNECTED MODELS ONLY

Floor Drain

The steamer should be located close to but not over a floor drain. Connect a ¾” ID reinforced rubber

hose rated for 212°F or higher to the drain fitting on rear of the steamer with a hose clamp.

Run the hose to the drain. DO NOT directly plumb the steamer to the drain, Leave a one-inch air gap

between the hose and the drain.

Optional Drain Connection

Run the hose to a funnel fitting leaving a one-inch gap between the hose and the top of the funnel as

shown in Fig 5. The drain hose must slope toward the floor drain or funnel.