WAter Line COnneCtiOn - COnneCteD MODeLS

The Installer/Owner is responsible for the water connection of this appliance. This appliance is to be installed

to comply with all applicable federal, state, or local plumbing codes. The installation requires a check-valve

(or other approved anti-back flow / anti-siphon device) (not provided) in all supply lines in accordance with and
as required by local, state, and national health, sanitation, and plumbing codes.

See Fig.7

Check local codes to determine exactly what type of anti-back flow / anti-siphon device is

necessary to meet local requirements.

Design the water supply line so the unit can be moved for service. Install a manual water

valve between the water supply line and the steamer supply line.

The Garden hose Thread (GhT) connector used must be suitable for potable water

Do not apply pipe thread sealant to GhT connections.

Install a manual water shut-off valve (not provided)

between the cold water supply line and the

appliance.

Either hot or cold water can be connected to the steamer. If hot is used, temperature

must be less than 180°F.

A reinforced rubber or braided stainless steel appliance hose rated for the temperature and

pressure of the water supply with a 3/4” garden hose type connection is required.

The hose must not be sharply bent, kinked or twisted.

If the steamer is close to a wall, use a right angle fitting to prevent kinking the hose

Flush the water supply lines before connecting the lines to the appliance.

Connect the water supply lines to the steamer.

QUICK DISCONNECT GAS CONNECTION - CUSTOMER

SUPPLIED

WATER LINE CONNECTION - CUSTOMER

SUPPLIED - 60 PSI MAXIMUM WATER PRESSURE

DRAIN HOSE - CUSTOMER SUPPLIED

Fig. 7