MP4010-1003

EVOLUTION GAS STEAMER

5

STAND INSTALLATION

If a AccuTemp Evolution Gas Steamer Stand is used ensure the floor is level and place the two lock-

ing casters to the “ON” position.

All AccuTemp Evolution Gas Steamer Stand with casters, shall be made with a connector that com-

plies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or CAN/CGA 6.16

and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use

with Gas Fuel, ANSI Z21.41 or CAN1-6.9.

WARNING

When using a stand that is equipped with casters, the floor surface must be level and

flat. Failure to do so can result in a “tipping” hazard that could result in

serious injury.

SINGLE STEAMER STAND INSTALLATION

The AccuTemp single stand can be equipped with adjustable height feet or non-adjustable casters.

Before mounting a steamer on the stand with casters, engage the two front locking casters, pressing

on the “ON” handle of the brake mechanism. To mount the steamer, carefully lift and place it on the

horizontal mounting brackets ensuring that the (4) mounting holes on the underside of the Evolution

are lined up with mounting holes of the brackets. Then, using a 7/16” wrench, fasten one pair of the

1/4” -20 hex bolt and 1/4” split lock washer through the underside of each stand bracket mounting

hole into the Evolution and tighten securely. With the SNh10 stand, level the steamer by adjusting the

feet found at the ends of each stand leg, either up or down as needed.

DOUBLE STEAMER STAND INSTALLATION

The AccuTemp double stand can be equipped with adjustable height feet or can be equipped with

non-adjustable casters and accommodates (2) E6 model Evolutions. Before mounting a steamer

on a stand with casters engage the brakes on the two front locking casters, pressing on the “ON”

handle of the brake mechanism. Always mount the first EVOLUTION on the bottom of the stand. To

mount the bottom steamer, carefully lift and place it on the horizontal mounting brackets, ensuring

that the (4) mounting holes on the underside of the Evolution are lined up with the mounting holes on

the brackets. Then, using a 7/16” wrench, fasten one pair of the 1/4"-20 hex bolts and 1/4" split lock

washers through the underside of each stand bracket mounting hole into the Evolution and tighten

securely. Once the bottom steamer has been installed, carefully lift and place the top Evolution

steamer on the horizontal mounting brackets, ensuring that the (4) mounting holes on the underside

of the Evolution are lined up with the mounting holes on the brackets. Then, using a 7/16” wrench,

fasten one pair of the 1/4"-20 hex bolts and 1/4" split lock washers through the underside of each

stand bracket mounting hole and tighten securely. With the SNh20 stand, level the appliances by

adjusting the feet found at the ends of each stand leg, either up or down as needed.