DAILY CLEANING

Turn the steamer off and wait for the steamer to cool.

1.

Open the drain valve and allow the cooking compartment to drain completely. Remove the

2.

pan racks, steam collector, overfill sensor and condensate tray for cleaning. Wipe the inside

of the cooking chamber, water sensors, pan rails, steam collector, overfill sensor, and

condensate tray with a clean cloth. Clean the door gasket, inside of door and front face of the

cooking chamber.

Re-install the overfill sensor, steam collector, pan rails and condensate tray. Leave the door

3.

open overnight.

(NOTE: The steamer will not operate without the overfill sensor.)

WEEKLY CLEANING

Close the drain valve and add 1 cup (8 ounces or 0.24 liters) of white vinegar to the

1.

cooking compartment. Start the steamer in the Cook Mode. The cooking compartment will

automatically fill with water. After 15 minutes, turn the steamer off and allow the steamer

to cool. Then open the drain valve and allow the water in the cooking chamber to drain

completely.
To rinse close the drain valve and start the steamer in the Cook Mode. The cooking

2.

compartment will automatically fill with water. After 15 minutes turn the steamer off and allow

it to cool. Open the drain valve and let it drain completely.
Remove the pan rails, steam distributor, steam collector, overfill sensor and condensate tray

3.

for cleaning. Clean the water sensors with a non-metallic cleaning pad.
Wipe the inside of the cooking chamber, water sensors, pan rails (Fig. 13), steam

4.

distributor (Fig. 13), steam collector (Fig. 13), overfill sensor (Fig. 13), and condensate tray

with a clean cloth.
Install the overfill sensor and the steam collector , resting the steam distributor on top of the

5.

steam collector align the 4 retaining fasteners and hand tighten, then install the pan rails and

the condensate tray. Leave the door open overnight.

(NOTE: The steamer will not operate without the overfill sensor.)

WARNING

Warning: Do not use a water jet or pressure washer to clean the steamer

OPERATIONS

STEAM

DISTRIBUTOR

STEAM

COLLECTOR

PAN RAIL

OVER FILL

SENSOR

Fig. 15