Technical specifications, Maintenance and care – Karcher Système de recyclage des eaux usées WRP 16000 User Manual

Page 18

Advertising
background image

-

6

The bases of a safe operating of the equip-
ment is thr regularly maintenance accord-
ing to the following maintenance plan.
Use only original parts of the manufacturer
or part suggessted by him, such as

parts and wearing parts,

accessories parts,

operating materials,

cleaning agents.

ƽ

Danger

Risk of accident while working on the unit.
During all tasks

First switch-on in voltage-less state,
switch off the emergency stop switch
and secure it against being switched on
again.

Shut off water supply.

Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe

operation and maintenance on washing
systems with recycling unit.

Customer Service
Work designated with the sign “Cus-
tomer Service” may only be done by the
fitters of Kärcher Customer Service.

In order to guarantee a reliable operation
og the equipment, we success, you signed
a maintenance agreement. Please refer to
you local Kärcher service department.

Monitoring and regulating equipment

Float switch in the recycled water tank

S7 up

Recycled water tank full. Filling process is stopped.

S7 down

Recycled water tank is filled.
Delay 120 seconds.

S9 up

Switching off the fresh water supply. Indicator lamp "Fresh water supply" lights up yel-
low.

S9 down

Switching on the fresh water supply. Indicator lamp "Fresh water supply" lights up yel-
low.

S11 up

Dry run protection for washing system not active, no error message.

S11 down

Dry run protection for washing system active, error message on the washing system.

Floater switch in the pump basin

S5 top*

Pump basin overfilled. Starting the disposal via the recycled water tank into the chan-
nel

S5 bottom*

Pump basin is not overfilled, normal system operation.

S14 top

Pump basin full (with option salt water exfiltration).

S14 bottom

No function / switch point is not used

S15 top

Pump basin is not empty, normal system operation.

S15 bottom

Pump basin empty, dry run protection of immersion pump active, no filtration, no re-
flushing possible. System runs on fresh water.

* S5 optional

Technical specifications

WRP 8000

1.217-151.0

WRP 16000

1.217-152.0

Immersion pump Motor output

W

1300

1700

Voltage

V

230/1~

Power consumption

A

5,9

8,5

Flow rate at approx. 0.1 MPa (1 bar), approx.

m

3

/h

8

16

Pressure

MPa (bar)

max. 0.14 (1.4) max. 0.16 (1.6)

Entire unit

Filter capacity

m

3

/h

max. 10

max. 20

Voltage

V

230/1~

Frequency

Hz

50

Weight

kg

280

390

Width

mm

700

900

Depth

mm

620

780

Height

mm

1600

Maintenance and care

Maintenance instructions

Who may perform maintenance?

Maintenance contract

18

EN

Advertising
This manual is related to the following products: