Troubleshooting

218

10" Modero Widescreen Touch Panels

Troubleshooting Information (Cont.)

Symptom

Solution

My Modero panel isn’t appearing
in my Workspace window.

• Verify that the System number is the same on both the NetLinx

Workspace window and the System Settings page on the Modero
panel.

• Verify you have entered the proper NetLinx Master IP and connection

methods into the Master Connection section of the System Settings
page.

My Modero panel can’t obtain a
DHCP Address

In requesting a DHCP Address, the DHCP Server can take up to a few
minutes to provide the address.

• Verify there is an active Ethernet connection attached to the rear of

the Modero before beginning these procedures.

• Select Diagnostics > Network Address, from the Main menu and

verify the System number.

• If the IP Address field is still empty, give the Modero a few minutes to

negotiate a DHCP Address and try again.

My panel is not showing up in the
Virtual Master’s System list of
connected devices.

If you a Virtual Master has already connected to the target panel, the
G4 device retains the information of the previous Virtual Master System
number.

• Reboot the panel without the USB cable plugged into the panel.

• Configure NetLinx Studio for a Virtual Master connection. Note the

System Number used in the Edit Settings window.

• Stop communication on the Virtual Master by going to Settings >

Stop Communications.

• Click Yes to stop communication.

• Select the System Number (from the Online Tree tab) and use a right

mouse click to select Refresh System. This re-establishes
communication with the Virtual Master.

• Plug-in the mini-USB cable into the corresponding port on the panel.

• Wait a few seconds and refresh the system. This re-establishes

communication with the Virtual Master. The panel should now appear
in the list of available devices.