Message lists, Warning messages – Sony VPL-VW100 User Manual

Page 61

Advertising
background image

61

GB

Troubleshooting

Ot
h

e

rs

Warning messages

Symptom

Cause and Remedy

LAMP/COVER flashes.

c Close the top cover and the lamp cover securely, or attach the

filter holder securely. (

1 pages 63 and 67)

LAMP/COVER lights up.

c The lamp has reached the end of its useful lifespan. Replace the

lamp. (

1 page 63)

c The lamp has reached a high temperature. Wait until the lamp

cools, and then turn on the power again. (

1 page 32)

TEMP/FAN flashes.

c The fan is broken. Consult with qualified Sony personnel.

TEMP/FAN lights up.

c The internal temperature is unusually high. Check to ensure that

if nothing is blocking the ventilation holes or whether or not the
projector is being used at high altitudes.

LAMP/COVER and
TEMP/FAN light up.

c Disconnect the AC power cord, re-connect it, then turn on the

power again. If the indicators still light up, the electrical system
has a problem. Consult with qualified Sony personnel.

Message Lists

Message

Cause and Remedy

High temp.! Lamp off in 1
min.

c Turn off the power.
c Check to ensure that nothing is blocking the ventilation holes.

(

1 page 14)

Frequency is out of range!

c Frequency is out of range. Input a signal that is within the

acceptable frequency range of the projector.

Please check Input-A
Signal Sel.

c Set “Input-A Signal Sel.” in the Setup

menu to

“Computer” when an RGB signal is input from a computer. (

1

page 53)

Please check DVI Signal
Sel.

c Set “DVI Signal Sel.” in the Setup

menu to “Computer”

when an RGB signal is input from a computer. (

1 page 53)

Note
Be sure to remove the DVI cable to disconnect the connection
between the projector and a digital tuner and so on, before setting
“DVI Signal Sel.”

Please replace the Lamp/
Filter.
Lamp/Filter life remains
less than 50H.

c The lifespan of the lamp and the air filter is running out. (50

hours is an approximate figure.)

Please replace the Lamp/
Filter.
Lamp/Filter life remains
less than 15H.

c The lifespan of the lamp and the air filter is running out. (15

hours is an approximate figure.)

Advertising