2 oscillator lock register, 3 user leds control register, 4 push button interrupt register – ARM IM-AD1 User Manual

Page 57

Advertising
background image

Reference Design Example

ARM DUI 0163B

Copyright © 2001-2003. All rights reserved.

4-11

4.2.2

Oscillator lock register

The lock register is used to control access to the oscillator registers, allowing them to
be locked and unlocked. This mechanism prevents the oscillator registers from being
overwritten accidently. Table 4-6 describes the lock register bits.

4.2.3

User LEDs control register

The LEDs register is a 9-bit register used to control the nine user LEDs on the logic
module. Writing a 0 to a bit lights the associated LED.

4.2.4

Push button interrupt register

The push button interrupt register contains 1 bit. It is a latched indication that the push
button on the logic module has been pressed. The output from this register is used to
drive an input to the interrupt controller. Table 4-7 describes the operation of this
register.

Table 4-6 LM_LOCK register

Bits

Name

Access

Function

16

LOCKED

Read

This bit indicates if the oscillator registers are
locked or unlocked:

0 = unlocked

1 = locked.

15:0

LOCKVAL

Read/write

Write the value

0x0000A05F

to this register to

enable write accesses to the oscillator
registers.

Write any other value to this register to lock
the oscillator registers.

Table 4-7 LM_INT register

Bits

Name

Access

Function

0

LM_INT

Read

This bit when SET is a latched indication that
the push button has been pressed.

Write

Write 0 to this register to CLEAR the latched
indication.

Writing 1 to this register has the same effect as
pressing the push button.