Installation

F232085

22

The threaded end of the bolts should extend 2 inches
(5 cm) above the surface of the floor.

Refer to Figure 5 for a typical installation of individual
mounting bolts on a UW60.

A bolt-locator fixture or rebar frame is available as an
option. This rigid welded assembly made of
reinforcing rod and mounting bolts is designed to be
embedded in concrete. Refer to Figure 6.

Figure 6

If the existing floor is not reinforced concrete at least
6 inches (15 cm) thick over a solid foundation, cut a
hole approximately 5 feet square through the existing
floor. Excavate to a depth of 6 inches (15 cm) from the
top of the existing floor. Produce a pyramid-shaped
hole by excavating the bottom of the hole to a width
6 inches (15 cm) wider on each side than the width of
the top of the hole. Fill with 6 inches of reinforced
concrete. Embed the mounting bolts or base frame as
the concrete is poured. Ensure that the bolt threads
extend 2 inches (5 cm) above floor level.

NOTE: Concrete should be poured at least
12 inches (30 cm) under the existing floor on all
four sides and tied in with rebar.

PHM178N

1

Frame

2

Grout

Figure 5

1

2

8 in.

(203 mm)

2 in.

(51 mm)

3/4 in.

(19 mm)

P035I

1

Machine Base

2

Mounting Bolt Threads

3

Grouting

4

Reinforcing Rod

P03 I

1

2

3

4