Installation

F232085

24

Drain Connection

A drain system of adequate capacity is essential to
washer-extractor performance. Ideally, the water
should empty through a vented pipe directly into a
sump or floor drain. Figures 9 and 10 show drain line
and drain trough configurations.

Figure 9

A flexible connection must be made to a vented drain
system to prevent an air lock and to prevent siphoning.

IMPORTANT: Washer-extractor must be installed
in accordance with all local codes and ordinances.

IMPORTANT: The top of the vent must be 1 foot
(30 cm) lower than the bottom of the dispenser.

If proper drain size is not available or practical, a surge
tank is required. A surge tank in conjunction with a
sump pump should be used when gravity drainage is
not possible, such as in below-ground-level
installations.

Before any deviation from specified installation
procedures is attempted, the customer or installer
should contact the distributor.

Increasing the drain hose length, installing elbows, or
causing bends will decrease drain flow rate and
increase drain times, impairing washer-extractor
performance.