Installation

27

F232085

Electrical Installation

IMPORTANT: Electrical ratings are subject to
change. Refer to serial decal for electrical ratings
information specific to your machine.

Electrical connections are made at the rear of the
control module. The machine must be connected to the
proper electrical supply shown on the identification
plate attached to the side of the control module.

IMPORTANT: Alliance Laundry Systems
warranty does not cover compounds that fail as a
result of improper input voltage.

NOTE: Do NOT use fuses in place of a circuit
breaker.

The washer-extractor should be connected to an
individual branch circuit not shared with lighting or
other equipment.

The connection should be shielded in a liquid-tight or
approved flexible conduit with proper conductors of
correct size installed in accordance with the National
Electric Code or other applicable codes. The
connection must be made by a qualified electrician
using the wiring diagram provided with the washer-
extractor.

Use wire sizes indicated in the Electrical
Specifications chart for runs up to 50 feet (15.24 m).
Use next larger size for runs of 50 to 100 feet (15.24 to
30.48 m). Use 2 sizes larger for runs greater than
100 feet (30.48 m).

For personal safety and for proper operation, the
washer-extractor must be grounded in accordance with
state and local codes. If such codes are not available,
grounding must conform with the National Electric
Code or other applicable codes. The ground
connection must be made to a proven earth ground, not
to conduit or water pipes.

This machine must be installed, adjusted,
and serviced by qualified electrical
maintenance personnel familiar with the
construction and operation of this type of
machinery. They must also be familiar with
the potential hazards involved. Failure to
observe this warning may result in
personal injury and/or equipment damage,
and may void the warranty.

SW004

WARNING

Dangerous voltages are present in the
electrical control box(es) and at the motor
terminals. Only qualified personnel
familiar with electrical test procedures,
test equipment, and safety precautions
should attempt adjustments and
troubleshooting. Disconnect power from
the machine before removing the control
box cover, and before attempting any
service procedures.

SW005

WARNING

Ensure that a ground wire from a proven
earth ground is connected to the ground
lug near the input power block on this
machine. Without proper grounding,
personal injury from electric shock could
occur and machine malfunctions may be
evident.

SW008

WARNING